This article applies to all JSDR software versions

Problem

This alarm indicates a DRVA has been unreachable for an extended time or a period that exceeds its set threshold.

image-20240604-043734.pngimage-20240604-043221.png

Possible Cause

  1. There are network connectivity issues between the MSA and the JetStream DRVA (via the management network).

  2. The DRVA is powered off or in a non-responsive state.

  3. The DRVA service is down.

  4. There is a communication issue between the host IOF and the DRVA.

\uD83C\uDF31 Solution

Gather the MSA support bundle before proceeding with the steps below.

  1. Check DRVA Status:

    • Login to the vCenter, navigate to JetStream DR → Appliances and validate the DRVA status.

    • Log in to the vCenter and navigate to the DRVA VM → Ensure the DRVA is powered on and running → Login to DRVA console, If the DRVA is unresponsive, try restarting.

    • Login to DRVA console and check if the DRVA service is running.

  2. Verify Network Connectivity:

    • Ensure required ports are enabled.

    • Check the network status between the MSA and the DRVA.

    • Ensure no firewalls or network security groups block DRVA management or data network.

    • Ensure host IOF to DRVA communication is intact.

Reach out to Jetstream Support with MSA logs if the issue persists.

What Routes need to be added for a dual Network DRVA
JetStream DR: DRVA unreachable duration exceeded
DRVA Diagnostic Tools
DRVA Connection Error

  • No labels