This article applies to all JSDR software versions
\uD83E\uDD14Â Problem
This alert indicates that the DRVA has been unreachable for a period that exceeds the threshold, or DRVA unavailable for an extensive period.
💡 Cause
Network connectivity issues between the MSA and the JetStream DRVA (managememnt network).
DRVA being powered off or in a non-responsive state.
DRVA service Down
Host IOF to DRVA communication issue.
\uD83C\uDF31Â Solution
Gather the MSA support bundle before proceeding with the steps below.
Check DRVA Status:
Login to the vCenter, navigate to JetStream DR → Appliances and validate the DRVA status.
Log in to the vCenter and navigate to the DRVA VM → Ensure the DRVA is powered on and running → Login to DRVA console, If the DRVA is unresponsive, try restarting.
Login to DRVA console and check if the DRVA service is running.
Verify Network Connectivity:
Ensure required ports are enabled.
Check the network status between the MSA and the DRVA.
Ensure no firewalls or network security groups block DRVA management or data network.
Ensure host IOF to DRVA communication is intact.
Reach out to Jetstream Support with MSA logs if the issue persists.
\uD83D\uDCCEÂ Related articles
What Routes need to be added for a dual Network DRVA
/wiki/spaces/KBDR/pages/2840461390
DRVA Diagnostic Tools
DRVA Connection Error