\uD83E\uDD14 Problem
After initial configuration and during storage site addition. You might encounter below error
Authentication with ObjectStore server failed. Please check that Management server time is synchronized and credentials are valid.
\uD83C\uDF31 Solution
This happens if MSA system clock and hw clock are not synced which needs validation.
#date – Command to check system clock time
#hwclock – Command to check hw clock time
Incase if you find both date/time being different and not in sync then we need to execute below command to synchronize both. After ensuring both clocks are in sync, please go ahead and try adding storage site again which should work.
hwclock --systohc
[ systohc stands for “system to hardware clock”, which copies the time from system to hardware clock ]
\uD83D\uDCCE Related articles
Filter by label
There are no items with the selected labels at this time.