\uD83E\uDD14 Problem

After initial configuration and during storage site addition. You might encounter below error

Authentication with ObjectStore server failed. Please check that Management server time is synchronized and credentials are valid.

\uD83C\uDF31 Solution

This happens if MSA system clock and hw clock are not in sync which needs validation.

#date – Command to check system clock time

#hwclock – Command to check hardware clock time

Incase if you find both date/time being different and not in sync then we need to execute below command to synchronize both. After ensuring both clocks are in sync, please go ahead and try adding storage site again which should work.

hwclock --systohc

[ systohc stands for “system to hardware clock”, which copies the time from system to hardware clock ]

Filter by label