Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This article applies to all JSDR software versions.

Alarm

This alarm indicates a DRVA has been unreachable for an extended time or a period that exceeds its set threshold.

...

  1. Check DRVA Status:

    • Log into vCenter, navigate to JetStream DR → Appliances and validate the DRVA status.

    • Log into vCenter and navigate to the DRVA VM.

      • Ensure the DRVA is powered on and running by logging into DRVA console.

      • If the DRVA is unresponsive, try restarting it.

    • Log into the DRVA console and check if the DRVA service is running.

  2. Verify Network Connectivity:

    • Ensure the required ports are enabled.

    • Check the network status between the MSA and the DRVA.

    • Ensure no firewalls or network security groups are blockin the DRVA management or data network.

    • Ensure there are no problems with the host IO filter to DRVA communications.

Note

Contact Jetstream Support with MSA logs if you are unable to resolve the issue persists.