This article applies to all JSDR software versions.
...
Alarm
This alarm indicates signals a DRVA has been unreachable for an extended time or a period that exceeds its set threshold.
...
Possible Cause
The DRVA can become unreachable if:
There are network connectivity issues between the MSA and the JetStream DRVA (via the management network).
The DRVA is powered off or in a non-responsive state.
The DRVA service is down.
There is a communication issue between the host
...
IO filter and the DRVA.
\uD83C\uDF31 Solution
...
Resolution
Info |
---|
Collect the /wiki/spaces/KBDR/pages/2784100547 before proceeding with the following steps below.: |
Check DRVA Status:
Login to the Log into vCenter, navigate to JetStream DR → Appliances and validate the DRVA status.
Log in to the into vCenter and navigate to the DRVA VM → .
Ensure the DRVA is powered on and running
by logging into DRVA console
.
If the DRVA is unresponsive, try restarting it.
Login to Log into the DRVA console and check if the DRVA service is running.
Verify Network Connectivity:
Ensure the required ports are enabled.
Check the network status between the MSA and the DRVA.
Ensure no firewalls or network security groups block are blockin the DRVA management or data network.
Ensure host IOF there are no problems with the host IO filter to DRVA communication is intactcommunications.
Infonote |
---|
Reach out to Contact Jetstream Support with MSA logs if you are unable to resolve the issue persists. |